Table 1 − Hydraulic Jacks − Values and Comparison
Application Group Jack Tightening
value [bar]
Comparison
[_(, mm]
Reset of jack /
round nut
[turns]
Lubricating
agent
2)
Foundation bolts 1112−1 94145 (1
st
step 1000) 1500 −
¼
No lubricant
Main bearing 1132−1 94114 1500 −
1
Oil
Engine stays 1715−1 94145 200 −
½
No lubricant
Tie rods 1903−1 94180 1500 from 100 to 1500 bar
ΔL=17 to 19mm
4¼
Molykote
paste G
Cylinder cover 2708−2 94215A 1500
652_ 2½
Oil
Exhaust valve
cage
2751−1 94252 1500
255_ 1
Oil
Top con rod 3303−1 94315 (1
st
step 1000) 1500
1
st
to 2
nd
step 20_ ½
Oil
Lower con rod 3303−2 94252 (1
st
step 700) 1500
1
st
to 2
nd
step 85_
1 Oil
Piston rod foot 3403−1 94340 (1
st
step 1000) 1500
1
st
to 2
nd
step 20_ ½
Oil
Piston head 3403−3 94340 1500
75_ ½
Oil
Bearing, supply
unit
5581−1 94557 1500 −
½
Oil
1)
For cutting out and cutting in of a fuel pump, see the Operation Manual
5556−2.
2)
For lubrication on threads and contact surfaces.