Maintenance
03301/A1
Winterthur Gas & Diesel Ltd.
25/ 25
Fuel Pump
Group
Key No.
Description Measuring
Direction
(method of
measuring)
Nominal
Dimension
(usual, new)
[mm]
Maximum Clearance,
Dimension
(because of wear)
[mm]
5556 Fuel pump
Plunger ( 42, 44 and 46 mm)
1 Clearance (plunger / cylinder) AB radial 0.0350.038 0.045
Clearance (plunger / cylinder) BC radial 0.0250.028 0.035
* Clearance (plunger / cylinder) D radial 0.0400.043 0.5
Guide piston outer 185
Lower housing inner 185
2 Clearance radial 0.150.68 0.8
3 Piston / lower spring carrier axial 0.120.24 0.3
4 Regulating sleeve / upper spring
carrier
axial 0 .50.7
0.8
5556 Roller guide
Pin outer
80
0
0.013
Guide piston (bore) inner
80
+ 0.04
+ 0.01
5 Clearance radial 0.0100.053 0.08
6 Total clearance between guide piston
and roller with pressure discs
axial 0.260.54
0.7
* Plunger conically machined in range ’C’’D’; i.e. clearance increases in
diameter of 0.015 mm.