Maintenance
03801/A1
Winterthur Gas & Diesel Ltd.
9/ 10
Group Component Work to be done Intervals & Lifetime
(operation hours)
7
Cylinder lube oil
filter
Replace filter element upstream of the cylinder
lubricating system
as necessary
8
81351
Exhaust Waste
Gate (LLT)
During a longer operation period at low engine
load, manually open the butterfly valve (refer to
the Operation Manual 81351)
In accordance with
instructions of valve
manufacturer
Servo oil service
pump (installed
on the engine)
Check rate of flow at max. pressure 30 000
Starting air pipes
on and upstream
of the engine
Drain (remove water) before and after each
maneuvering period
Pressure gauges
and pyrometers
Compare and calibrate according to master
instruments
60008000
Pipe holders Do a check of the screws at intervals. If
necessary, tighten the screws.
(first time after 100 Operation hours)
as necessary
84471 Servo oil pipes Grind the sealing faces as necessary
Non-return valve
(fuel inlet at the
fuel, rail)
Do a random check 18 000
84601 Hydraulic pipe for
exhaust valve
drive
Grind the sealing faces as necessary
87331 HP pipe to
injection valve
(on cylinder
cover)
Grind the sealing faces as necessary
Supply unit, fuel
drain pipes
Make sure that the pipes are not blocked 6000
87521 HP fuel pipe Grind the sealing faces as necessary
Inspection and Overhaul Intervals (Guidelines)