February 2013
2-31
ColorQube® 9303 Family
01H
Status Indicator RAPs
• The marking unit driver PWB, PL 92.10 Item 4, is driven from +24V from the IME control-
ler PWB
• Repair the wiring as necessary, REP 1.1
• If necessary, install a new IME controller PWB, PL 92.10 Item 1.
Marking Unit Driver PWB
• To view the +24V distribution from the IME controller PWB, refer to WD 9.7.
• For +24V faults on the marking unit driver PWB, refer to:
– WD 9.10
– WD 9.12
• The solenoid patch PWB, PL 93.10 Item 9 is driven from +24V from the marking unit
driver PWB:
• Repair the wiring as necessary, REP 1.1.
• If necessary, install a new marking unit driver PWB, PL 92.10 Item 4.
Solenoid Patch PWB
• To view the +24V distribution from the marking unit driver PWB, refer to WD 9.12.
• For +24V faults on the solenoid patch PWB, refer to:
– WD 9.14
– WD 9.15
• The components that follow are driven from +24V from the solenoid patch PWB:
– Purge solenoid valves 1 to 4 SOL93-059, 060, 061, 062, part of PL 93.10 Item 10.
– Black ink solenoid valves 5 to 8 SOL063,064, 065, 066, part of PL 93.10 Item 10
– Yellow ink solenoid valves 9 to 12,SOL067, 068, 069, 070, part of PL 93.10 Item 10
– Cyan ink solenoid valves 13 to 16 SOL071, 072, 073, 074, part of PL 93.10 Item 10
– Magenta ink solenoid valves 17 to 20 SOL075, 076, 077, 078, part of PL 93.10 Item
10
• Repair the wiring as necessary, REP 1.1.
• If necessary, install a new solenoid patch PWB, PL 93.10 Item 9.
Power Distribution PWB
• To view the +24V distribution from the power supply unit, refer to WD 1.5
• For +24V faults on the power distribution PWB, refer to:
– WD 1.6
– WD 1.7
• Check for +24V on both sides of fuse F8 on the power distribution PWB. If +24V is not
present, check the following wiring:
– Between PJ8 pins 7 and 9 on the power distribution PWB and PJ920 pins 1 and 3 on
the scanner PWB.
– Between PJ8 pins 1, 3 and 5 on the power distribution PWB and PJ188 pins 1, 2 and
3 on the DADH PWB.
• Repair the wiring as necessary, REP 1.1.
• If necessary, install a new power distribution PWB, PL 3.11 Item 1.
Scanner PWB
• To view the +24V distribution from the power distribution PWB, refer to WD 1.7
• For +24V faults on the scanner PWB, refer to:
– WD 6.1
– WD 6.2
• The components that follow are driven from +24V from the scanner PWB:
– LED exposure lamp(s), PL 62.15 Item 2.
• Repair the wiring as necessary, REP 1.1
• If necessary, install a new scanner PWB, PL 62.16 Item 8
DADH PWB
• To view the +24V distribution from the power distribution PWB, refer to WD 1.7.
• For +24V faults on the DADH PWB, refer to:
– WD 5.1
– WD 5.2
• The components that follow are driven from +24V from the DADH PWB:
– DADH CVT motor MOT05-099, PL 5.25 Item 9.
– DADH feed motor MOT05-074, PL 5.15 Item 16.
– DADH duplex solenoid SOL05-100, PL 5.30 Item 3.
– Nudger motor MOT05-098, PL 5.15 Item 5.
– DADH feed clutch CL05-062, PL 5.15 Item 9.
– DADH cover interlock switch S05-212, PL 5.15 Item 11.
• Repair the wiring as necessary, REP 1.1
• If necessary, install a new DADH PWB, PL 5.10 Item 5.
Media Path Driver PWB
• To view the +24V distribution from the power supply unit, refer to WD 1.5
• For +24V faults on the media path driver PWB, refer to:
– WD 8.2
– WD 8.3
– WD 8.4
– WD 8.5
• The components that follow are driven from +24V from the media path driver PWB:
– Bypass feed motor (M7) MOT74-420, PL 74.10 Item 2.
– 3 tray module PWB, PL 73.16 Item 4.
– Tray 5 control PWB, PL 75.68 Item 8.
–OCT, PL 12.00 Item 1.
– LCSS PWB, PL 12.75 Item 1.
– HVF PWB, PL 12.140 Item 2.
• Repair the wiring as necessary, REP 1.1.
• If necessary, install a new media path driver PWB, PL 1.15 Item 5
3 Tray Module PWB
• To view the +24 distribution from the media path driver PWB, refer to WD 8.2
• For +24V faults on the three trays module PWB, refer to:
– WD 7.3
– WD 7.4
– WD 7.5
• The +24V LED on this PWB is shown in WD 7.3
• The components that follow are driven from +24V from the 3 tray module PWB: