February 2013
2-33
ColorQube® 9303 Family
01H
Status Indicator RAPs
– Staple head 1 motor MOT12-247, part of PL 12.110 Item 12.
– Stapler unit 1 motor MOT12-249, PL 12.110 Item 27.
– Ejector motor MOT12-236, part of PL 12.110 Item 2.
– Ejector roll motor MOT12-233, part of PL 12.110 Item 2.
– Pressing & support motor MOT12-323, PL 12.110 Item 9.
– Front tamper motor MOT12-226, PL 12.125 Item 6.
– Punch unit motor MOT12-245, part of PL 12.125 Item 19.
– Punch head motor MOT12-244, part of PL 12.125 Item 19.
• Repair the wiring as necessary, REP 1.1.
• If necessary, install a new HVF PWB, PL 12.140 Item 2.
BM PWB (Booklet Maker)
• To view the +24V distribution from the HVF PWB, refer to WD 12.6.
• For +24V faults on the BM, refer to:
– WD 12.17
– WD 12.19
• The components that follow are driven from +24V from the BM PWB:
– BM SH1 motor MOT12-254, part of PL 12.185 Item 7.
– BM SH2 motor MOT12-275, part of PL 12.185 Item 7.
– BM compiler motor MOT 12-251, PL 12.175 Item 1.
– BM backstop motor MOT 12-255, PL 12.160 Item 4.
– BM tamper 1 motor MOT12-256, PL 12.155 Item 3.
– BM stack hold solenoid SOL12-259 (1 of 2), PL 12.165 Item 17.
– BM stack hold solenoid SOL12-259 (2 of 2), PL 12.165 Item 17.
– BM conveyor drive motor MOT12-274, PL 12.190 Item 4.
– BM crease roll gate motor MOT12-273, PL 12.175 Item 8.
– BM crease roll motor MOT12-253, PL 12.175 Item 12.
– BM crease blade motor MOT12-252, PL 12.170 Item 3.
– BM flapper motor MOT12-271, PL 12.175 Item 1.
• Repair the wiring as necessary, REP 1.1.
• If necessary, install a new BM PWB, PL 12.175 Item 10.
Tri-folder PWB
• To view the +24V distribution from the BM PWB, refer to WD 12.6.
• For +24V faults on the tri-folder PWB, refer to WD 12.20.
• The components that follow are driven from +24V from the tri folder PWB:
– Tri folder top cover interlock switch S12-210, PL 12.215 Item 3.
– Tri folder front door interlock switch S12-209, PL 12.215 Item 2.
– Tri folder diverter solenoid SOL12-267, PL 12.215 Item 16.
– Tri folder assist gate solenoid SOL12-268, PL 12.215 Item 8.
– Tri folder drive clutch CL12-269, PL 12.205 Item 9.
• Repair the wiring as necessary, REP 1.1.
• If necessary, install a new tri-folder PWB, PL 12.205 Item 16.
Inserter PWB
• To view the +24V distribution from the HVF PWB, refer to WD 12.14.
• For +24V faults on the inserter PWB, refer to:
– WD 12.21
– WD 12.22
• The components that follow are driven from +24V from the inserter PWB:
– Inserter top cover interlock switch S12-178, PL 12.305 Item 8.
– Inserter jam cover interlock switch S12-179, PL 12.300 Item 18.
– Inserter clutch CL12-260, PL 12.310 Item 3.
– Inserter motor MOT12-261, PL 12.315 Item 1.
• Repair the wiring as necessary, REP 1.1.
• If necessary, install a new inserter PWB, PL 12.310 Item 9.
OCT PWB
• To view the +24V distribution from the media path driver PWB, refer to WD 8.5.
• For +24V faults on the OCT PWB, refer to WD 12.23.
• The OCT offset motor MOT12-300, part of PL 12.00 Item 1, is driven from +24V from the
inserter PWB
• Repair the wiring as necessary, REP 1.1.
• If necessary, install a new OCT, PL 12.00 Item 1.
Cleaning Unit
• To view the +24V distribution from the drum driver PWB, refer to WD 9.2
• For +24V faults on the cleaning unit PWB, refer to WD 9.19
• The cleaning unit solenoid valve, part of PL 94.10 Item 21, is driven from +24V from the
cleaning unit PWB:
• Repair the wiring as necessary, REP 1.1.
• If necessary, install a new cleaning unit, PL 94.10 Item 21.
NOTE: The cleaning unit PWB is not spared individually, the next highest assembly is the
cleaning unit.
Figure 1 Component location
LEDs
Power supply unit