February 2013
2-62
ColorQube® 9303 Family
05-345-00, 05-346-00
Status Indicator RAPs
NOTE: The exit roll idlers remain lowered for 30 seconds.
Enter dC330 code 05-100 to energize the DADH duplex solenoid, SOL05-100, PL 5.30 Item 3,
to lower the exit roll idlers PL 5.30 Item 6.
The exit roll idlers lower.
YN
Perform the steps that follow:
•Refer to WD 5.1. Check SOL05-100.
References:
– GP 12 How to Check a Solenoid or Clutch.
– P/J181, DADH PWB and P/J205.
– 01H +24V Distribution RAP.
– 01L 0V Distribution RAP.
• Check the baffle assembly link arm, PL 5.30 Item 11. Make sure that the link arm is
connected correctly to the DADH duplex solenoid, refer to REP 5.5.
Install new components as necessary:
• DADH duplex solenoid, PL 5.30 Item 3.
• DADH PWB, PL 5.10 Item 5.
• Lower baffle assembly, PL 5.30 Item 14.
Enter dC330 code 05-074 to run the DADH feed motor, MOT05-074, PL 5.15 Item 16.
MOT05-074 runs.
YN
Go to the 05C DADH Motor Failure RAP.
The exit roll rotates.
YN
Perform the steps that follow:
• Check the feed motor drive belt, PL 5.35 Item 5.
• Check the feed motor tension spring, PL 5.15 Item 17. Check the feed motor drive
belt tension, ADJ 5.1.
• Check the exit roll and pulley, PL 5.35 Item 6 and PL 5.35 Item 15.
If necessary, install a new DADH input tray assembly, PL 5.35 Item 1.
The fault only occurs in duplex mode.
YN
Go to the Final Checkout.
NOTE: During normal operation, the exit roll idlers remain raised (closed) in simplex mode. In
duplex mode, the exit roll idlers remain raised unless the document is longer than 280 mm (11
inches). The exit roll idlers raise and lower while feeding longer documents in duplex mode.
Exit diagnostics mode. Close the DADH top cover. Make two copies in duplex mode. Check
that the second document is held in the feed rolls, PL 5.15 Item 1, until the first document is fed
into the output tray.
The feed rolls held the second document.
YN
Go to the 05D DADH Feed Clutch Failure RAP.
Go to the Final Checkout.
Final Checkout
Perform the steps that follow:
• For 05-345-00 and 05-346-00 faults:
– Check that the pre-scan idlers are clean and rotate freely, refer to ADJ 5.4.
– Check that the post-scan idlers are clean and rotate freely, refer to ADJ 5.4.
– Check the CVT ramp assembly for damage and rough edges, PL 62.10 Item 5.
– Check the duplex gate for damage and rough edges, PL 5.25 Item 12.
– Check that the DADH exit sensor, Q05-209 is installed correctly, PL 5.30 Item 13.
– Make sure that the DADH ground harness is connected correctly, PL 5.10 Item 11.
– Make sure the DADH feed motor drive belt and DADH CVT motor drive belt are ten-
sioned correctly, ADJ 5.1.
Install new components as necessary:
– Top access cover assembly, PL 5.20 Item 17.
– Lower baffle assembly, PL 5.30 Item 14.
• For 05-346-00 faults:
– Make sure that the exit rolls are clean and rotate freely, refer to ADJ 5.4.
– Make sure that the exit roll idlers are clean and rotate freely, refer to ADJ 5.4.
– Make sure the tension springs on the exit roll shaft are in the correct position, refer to
REP 5.5
– Check the exit roll static eliminator and ground harness, PL 5.35 Item 7.
– Check the restack arm for damage or rough edges, PL 5.35 Item 3.
Install new components as necessary:
– DADH exit roll, PL 5.35 Item 6.
– DADH input tray assembly, PL 5.35 Item 1.
If the fault continues, make sure that all documents correctly exit the previous sensor in the
document path. Refer to the 05-340-00 DADH Pre-Reg Sensor Failure RAP.
A