2-38
Fuel system
Fuel system
High-pressure fuel pump control
The high-pressure fuel pump operates for 5 seconds after the “POWER” switch is turned to ON, and
always operates while the engine is running.
The fuel pump continues to operate for 7 second after the engine is turned OFF.
After the “POWER” switch is turned to ON, all injectors are activated one time to prevent clogging be-
fore the high-pressure fuel pump operates.
Low-pressure fuel pump control
Between idle and 1100 r/min, the pump will cycle ON for 10 seconds and OFF for 20 seconds.
Above 1100 r/min, the pump is ON continuously.