8.3 Alarm Message List
8-16
1031
MEMORY
ERROR
(MOTION1)
The file data used by MOTION are damaged.
Initialize the damaged file in the maintenance
mode.
62 • The linear scale condition file is
damaged.
63 • The gauging sensor file is dam-
aged.
64 • The conveyor condition auxiliary
file is damaged.
1050
SET-UP
PROCESS
ERROR
(SYSCON)
1 An error occurred in the setup pro-
cessing of the system when the
control power turned ON (Setup
error).
The motion instruction did not start
up. (motion instruction setup incom-
plete.)
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
1050
SET-UP
PROCESS
ERROR
(SYSCON)
2 An error occurred in the setup pro-
cessing of the system when the
control power turned ON (Process-
ing timeout).
The motion instruction did not start
up. (Setup of the servo control cir-
cuit board and NCP02 circuit board
incomplete, parameter setting value
error)
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
1051
SET-UP PRO-
CESS ERROR
(MOTION)
An error occurred in the setup process of
MOTION when the control power turned ON.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
1 • The servo control section was not
started up.
2 • The position data of when the
power supply had turned OFF
could not be transmitted to the
servo control section.
3 • The servo control section could
not receive the position data of
when the power supply had
turned OFF.
5 • The request to turn ON the PG
power supply for the mounted
axis could not be sent.
6 • The PG power supply for the
mounted axis could not turn ON.
7 • The request to prepare a feed-
back pulse could not be sent.
8 • The feedback pulse could not be
prepared.
9 • The request to initialize the arith-
metic section could not be sent.
10 • The arithmetic section could not
be initialized.
11 • The request to prepare the current
value could not be sent.
12 • The current value could not be
prepared.
1100
SYSTEM
ERROR
--- An unknown alarm was detected
because of noise or control error.
Contact your Yaskawa representative.
1101
SYSTEM
ERROR
(SYSTEM 1)
--- An error occurred during the sys-
tem control check.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.