8.3 Alarm Message List
8-45
4130
NETWORK
APPLICATION
ERROR
101 An error occurred in the buffer for
request to write PCI getting process
of the Ethernet function.
• Rotate the mode selector switch on the pro-
gramming pendant to release the mode set-
ting which has been set to "REMOTE", then
rotate the switch again to set back to
"REMOTE".
• If the error occurs again after releasing the
mode setting of the switch and setting back
to "REMOTE", turn the power OFF then
back ON.
If the error occurs again, contact your
Yaskawa representative.
200 The socket of the Ethernet function
was full and was not able to create
a socket.
201 An error occurred in the semaphore
of socket control table of the Ether-
net function.
4131
UDP COMMUNI-
CATION ERROR
1 An error occurred in the creation of
receiving socket during the UDP
process of the Ethernet function.
• Rotate the mode selector switch on the pro-
gramming pendant to release the mode set-
ting which has been set to "REMOTE", then
rotate the switch again to set back to
"REMOTE".
• If the error occurs again after releasing the
mode setting of the switch and setting back
to "REMOTE", turn the power OFF then
back ON.
If the error occurs again, contact your
Yaskawa representative.
2 An error occurred in the creation of
transmission socket during the
UDP process of the Ethernet func-
tion.
3 Illegal data were received in the
UDP process of the Ethernet func-
tion.
4 Transmission error occurred in the
UDP process of the Ethernet func-
tion.
5 The SELECT operation was not
successfully completed in the UDP
process of the Ethernet function.
100 The re-initialization notification of
illegal data length was received in
the UDP process of the Ethernet
function.
101 The re-initialization notification of
illegal data was received in the
UDP process of the Ethernet func-
tion.
102 The PCI write process was not suc-
cessfully completed in the UDP pro-
cess of the Ethernet function.
103 The transmission request of illegal
data length was received in the
UDP process of the Ethernet func-
tion.
104 The transmission request of illegal
data was received in the UDP pro-
cess of the Ethernet function.
4132
TCP COMMUNI-
CATION ERROR
1 The socket table was not success-
fully created in the TCP process of
the Ethernet function.
• Rotate the mode selector switch on the pro-
gramming pendant to release the mode set-
ting which has been set to "REMOTE", then
rotate the switch again to set back to
"REMOTE".
• If the error occurs again after releasing the
mode setting of the switch and setting back
to "REMOTE", turn the power OFF then
back ON.
If the error occurs again, contact your
Yaskawa representative.
2 An error occurred in the process of
the TCP server initialization of the
Ethernet function.
3 An error occurred in connection
detecting process of TCP server of
the Ethernet function.
4 An error occurred in the connection
detection checking process of TCP
server of the Ethernet function.
Alarm Message List
Alarm
Number
Message
Sub
Code
Cause Remedy