8.3 Alarm Message List
8-46
4135
TOYOPUC RUN
STOP
0 TOYOPUC is in stopped state. Use the PCwin, etc. to run the TOYOPUC,
then reset the alarm for the NX100, or turn
ON the power supply again.
4136
TOYOPUC
MAJOR ERROR
0 The PCI bus state of the TOYO-
PUC turns to "ER".
An error occurred in the processing
on the TOYOPUC side.
• Rotate the mode selector switch on the pro-
gramming pendant to release the mode set-
ting which has been set to "REMOTE", then
rotate the switch again to set back to
"REMOTE".
• If the error occurs again after releasing the
mode setting of the switch and setting back
to "REMOTE", turn the power OFF then
back ON.
If the error occurs again, contact your
Yaskawa representative.
1 INTRB time-out error
An error occurred in the PCI bus
communication processing of the
TOYOPUC.
2 The INTPC does not turn to "1" five
seconds after the PCI command is
issued.
An error occurred in the PCI bus
communication processing of the
TOYOPUC.
3 Error in the state of interrupt
register1
An error occurred in the PCI bus
communication processing of the
TOYOPUC
4137
SETUALM
ERROR
1 An error occurred at SETUALM
instruction execution.
Alarm code specification error
Specify the alarm in the range 8000 to 8999.
2 An error occurred at SETUALM
instruction execution.
Task specification error
Specify the task in the range 0 to 4 (7 at
expansion).
3 An error occurred at SETUALM
instruction execution.
Motion mode specification error
Set the motion mode to 0 or 1.
4138 SVON ERROR
--- An error occurred at SVON instruc-
tion execution.
SVON is disabled.
• Verify that the external servo ON (EXSVON)
is short-circuited.
• Verify that the concurrent I/O signal #80031
(servo ON condition1) and #80033 (servo
ON condition2) are turned ON.
4139 PRINT ERROR --- An error occurred at PRINT instruc-
tion execution.
PRINT output conversion spec
(character string specification) error
Review the PRINT output conversion spec
(character string specification).
4140 DIALOG ERROR
An error occurred at execution of the DIA-
LOG instruction.
1 DIALOG instruction control error • Reset the alarm, and then try again.
• Turn the power OFF and back ON.
2 Messages and buttons are not reg-
istere.
Review DIALOG instruction.3 Buttons are not registered.
4 The length of character string was
exceeded.
4141 SNTP ERROR
1 The error on setting of time differ-
ence value occurred in the SNTP
process of the Ethernet function.
• Turn the power OFF and back ON.
If the error occurs again, contact your
Yaskawa representative.
2 The error on setting of time-out
value occurred in the SNTP pro-
cess of the Ethernet function.
3 The error on setting of reference
interval value occurred in the SNTP
process of the Ethernet function.
Alarm Message List
Alarm
Number
Message
Sub
Code
Cause Remedy