8.3 Alarm Message List
8-48
4201
SYSTEM
ERROR (JOB)
-10 • An error occurred in job data con-
trol system.
• Reset the alarm, and then try again.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
-11 • An error occurred in sequence
number of the accessed job.
-12 • An error occurred in step number
of the accessed job.
-13 • A job specified at job search did
not exist in the memory.
-14 • There was an instruction that did
not exist in a job because of
inconsistency of the system soft-
ware.
Check the NCP01 and NCP02 software ver-
sions before/after updating.
-16 • Unused handles were lacking
when an attempt was made to
open a job.
• Reset the alarm, and then try again.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
-18 • The number of instructions added
to a job exceeded 9999.
Delete unnecessary instructions and add
new instructions.
-19 • The number of steps added to a
job exceeded 9999.
Delete unnecessary steps and add new
steps.
-20 • A job was newly created with the
same name of the undefined job
already specified in the memory.
• Reset the alarm, and then try again.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
-99 • A job data in the memory was
destroyed.
4202
SYSTEM
ERROR
(JOB)
An error occurred when accessing to job
data.
• Reset the alarm, and then try again.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
1 • An error occurred in parameter
specification.
2 • Access time exceeded the limit.
3 • The access to a job could not be
performed with the specified job
name.
4 • The character not allowed was
used as a job name.
5 • A job was newly created with the
same name of the job already
specified in the memory.
6 • The allowable job registration
area (memory) was exceeded.
Delete unused jobs and/or expand CMOS.
7 • A job that did not exist in the
memory was specified.
• Reset the alarm, and then try again.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
8 • An attempt was made to change
the contents for the job prohibited
from being edited.
Release the prohibition and change it.
9 • An error occurred in handle value.
• Reset the alarm, and then try again.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
10 • An error occurred in job data con-
trol system.
11 • An error occurred in sequence
number of the accessed job.
Alarm Message List
Alarm
Number
Message
Sub
Code
Cause Remedy