EasyManua.ls Logo

YASKAWA NX100 - Page 152

YASKAWA NX100
247 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8.3 Alarm Message List
8-48
4201
SYSTEM
ERROR (JOB)
-10 • An error occurred in job data con-
trol system.
• Reset the alarm, and then try again.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
-11 • An error occurred in sequence
number of the accessed job.
-12 • An error occurred in step number
of the accessed job.
-13 • A job specified at job search did
not exist in the memory.
-14 • There was an instruction that did
not exist in a job because of
inconsistency of the system soft-
ware.
Check the NCP01 and NCP02 software ver-
sions before/after updating.
-16 • Unused handles were lacking
when an attempt was made to
open a job.
• Reset the alarm, and then try again.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
-18 • The number of instructions added
to a job exceeded 9999.
Delete unnecessary instructions and add
new instructions.
-19 • The number of steps added to a
job exceeded 9999.
Delete unnecessary steps and add new
steps.
-20 • A job was newly created with the
same name of the undefined job
already specified in the memory.
• Reset the alarm, and then try again.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
-99 • A job data in the memory was
destroyed.
4202
SYSTEM
ERROR
(JOB)
An error occurred when accessing to job
data.
• Reset the alarm, and then try again.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
1 • An error occurred in parameter
specification.
2 • Access time exceeded the limit.
3 • The access to a job could not be
performed with the specified job
name.
4 • The character not allowed was
used as a job name.
5 • A job was newly created with the
same name of the job already
specified in the memory.
6 • The allowable job registration
area (memory) was exceeded.
Delete unused jobs and/or expand CMOS.
7 • A job that did not exist in the
memory was specified.
• Reset the alarm, and then try again.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
8 • An attempt was made to change
the contents for the job prohibited
from being edited.
Release the prohibition and change it.
9 • An error occurred in handle value.
• Reset the alarm, and then try again.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
10 • An error occurred in job data con-
trol system.
11 • An error occurred in sequence
number of the accessed job.
Alarm Message List
Alarm
Number
Message
Sub
Code
Cause Remedy

Table of Contents

Other manuals for YASKAWA NX100

Related product manuals