8.3 Alarm Message List
8-104
4609
MEMORY PLAY
FILE ERROR
An error occurred when executing the memo
play operation.
Correct the job.
2 • The memory play file was being
used in another system.
5 • The control group in the memory
play file did not agree with the
control group of execution job.
6 • An attempt was made to clear the
memory play file by a CLEAR
instruction before having exe-
cuted a MEMOF instruction.
4610
MEMORY PLAY
SAMPLING
ERROR
An internal control error occurred at memory
play sampling.
• Reset the alarm, and then try again.
If the error occurs again, contact your
Yaskawa representative.
1 • Failed to read the memory play
sampling data.
2 • Failed to write the memory play
sampling data.
3 • Failed to seek the memory play
sampling data.
4 • Incorrect mode setting at memory
play sampling
Correctly set the memory play mode.
5 • Incorrect designation of the con-
trol group at memory play sam-
pling
• Reset the alarm, and then try again.
If the error occurs again, contact your
Yaskawa representative.
4610
MEMORY PLAY
SAMPLING
ERROR
An internal control error occurred at memory
play sampling.
• Reset the alarm, and then try again.
If the error occurs again, contact your
Yaskawa representative.
6• K/N < 0 in the memory play sam-
pling section
7 • The memory play sampling data
back-play mode could not be
detected.
8 • The memory play sampling data
could not be initialized.
4611 OPTON
INSTRUCTION
EXECUTION
NUMBER OVER
--- An error occurred when executing a
OPTON instruction.
• The number of times that the
OPTON instruction was executed
exceeded the limit value.
Correct the OPTON instruction.
4612 TSYNC ERROR --- An error occurred at the execution
of the TSYNC instruction.
• The number of synchronizations
(SNUM) specified by the TSYNC
instruction disagreed. (Sub code:
the number of synchronizations of
the first executed TSYNC)
Set the same number of synchronizations of
the TSYNC instruction.
Alarm Message List
Alarm
Number
Message
Sub
Code
Cause Remedy