15.4 The Class Setup Screen
Use this screen to add, edit or delete classifiers. A classifier groups traffic into data
flows according to specific criteria such as the source address, destination
address, source port number, destination port number or incoming interface. For
example, you can configure a classifier to select traffic from the same protocol
port (such as Telnet) to form a flow.
Click Advanced > QoS > Class Setup to open the following screen.
Figure 98 Advanced > QoS > Class Setup
The following table describes the labels in this screen.
Traffic priority
will be
automatically
assigned by
These fields are ignored if traffic matches a class you configured in the
Class Setup screen.
If you select ON and traffic does not match a class configured in the
Class Setup screen, the P-792H v2 assigns priority to unmatched traffic
based on the IEEE 802.1p priority level, IP precedence and/or packet
length. See Section 15.6.4 on page 216 for more information.
If you select OFF, traffic which does not match a class is mapped to
queue two.
Apply Click this to save your changes.
Cancel Click this to restore your previously saved settings.
Table 62 Advanced > QoS > General
LABEL DESCRIPTION
Table 63 Advanced > QoS > Class Setup
LABEL DESCRIPTION
Create a new
Class
Click Add to create a new classifier.
No This is the number of each classifier. The ordering of the classifiers is
important as the classifiers are applied in turn.
Active Select the check box to enable this classifier.
Name This is the name of the classifier.