3 Run the HyperTerminal program by clicking Transfer, then Send File as shown in
the following screen.
Figure 208 Restore Configuration Example
4 After a successful restoration you will see the following screen. Press any key to
restart the P-792H v2 and return to the SMT menu.
Figure 209 Successful Restoration Confirmation Screen
35.5 Uploading Firmware and Configuration Files
This section shows you how to upload firmware and configuration files. You can
upload configuration files by following the procedure in Section 35.4 on page 375
or by following the instructions in Menu 24.7.2 - System Maintenance -
Upload System Configuration File (for console port).
Do not interrupt the file transfer process as this may
PERMANENTLY DAMAGE YOUR P-792H v2.
35.5.1 Firmware File Upload
FTP is the preferred method for uploading the firmware and configuration. To use
this feature, your computer must have an FTP client.
Type the configuration file’s
location, or click Browse to
Choose the Xmodem protocol.
Then click Send.
Save to ROM
Hit any key to start system reboot.