Installation
154
Aastra 470 ab R3.0
syd-0337/1.5 – R3.0 – 05.2013
FXS mode: Control input
If FXS interfaces are configured as control inputs, one or more of the switch groups
1...20 can be switched between position 1, 2 and 3. An external switch or a relay is
connected for this purpose. An LED can be connected to the circuit to indicate the
switch state. The no-load voltage is 24 VDC; the current is limited to 25mA.
The permissible switch and loop resistances are as follows:
Active state (On): < 1 k
Passive state (Off): > 4 k
There are no special requirements for the cables.
Warning
Control inputs must have a floating connection.
Fig. 60 Connection for FXS mode: Control input
In the switch group configuration in AMS the ports are assigned to the control in-
puts of a switch group. To be able to control all 3 switch positions of a switch group,
you need 2 control inputs which switch the switch position of the switch group de-
pending on the status.
Tab. 70 Switch group control via the control inputs
Other conditions:
The same control inputs can control one or more switch groups.
The same switch group can only be switched by the 2 assigned control inputs.
Control of the switch groups using the control inputs takes priority over control
using function codes.
FXS control input 1 FXS control input 2 Switch positions of the switch group
Off Off Position 1
On Off Position 2
Random On Position 3
a
b
24 VDC
25mA
FXS interface