Operation and Maintenance
248
Aastra 470 ab R3.0
syd-0337/1.5 – R3.0 – 05.2013
6. 6. 1. 1 Event types
Tab. 103 Event types, in alphabetical order
Event / error message Trigger condition Details
AastraSIP terminals back
within the licence limit
Aastra SIP Terminals and Aastra Video Terminals
are now available.
Parameter 1=1: Aastra SIP Ter-
minals licence, parameter 2=1:
Aastra Video Terminals licence,
data, time
Application card CPU2: Data
communication out of service
Data communications with the CPU2 applica-
tions card have been interrupted for an unusu-
ally long period of time (1 hour) due to an error
(after a Windows update or due to other rea-
sons).
Date, time
Application card CPU2: Data
communications back in ser-
vice
Data communications with the CPU2 applica-
tions card have been restored.
Date, time
ATAS: connection established ATAS: connection (re) established Date, time
ATAS: Connection lost ATAS: connection lost Cause (0: Logoff, 1: missing
cycle signal), date, time
BluStar Client back within the
licence limit
A sufficient number of licences is now available
again for BluStar clients.
Parameter 1: 0 (not used)
Licence type: 0 and 1: (not used), 2: BluStar CTI,
3: BluStar softphone, 4: BluStar video option,
5: BluStar presence option, 6: BluStar Microsoft
Lync Plugin, 7: BluStar IBM Sametime Plugin
Parameter 1, licence type, total
purchased licences, date, time
Card in service A card that was previously out of service is back
in service again.
Number of the expansion slot,
date, time
Card out of service A card previously in operation has stopped
functioning.
Number of the expansion slot,
date, time
CL Printer Jam • No response from system printer for past 4
minutes
• Printer out of paper or switched off
interface, interfaces/card num-
ber, port number, date, time
CL-Printer available again Printout on the system printer available once
again
Date, time
Compatible PMS application The external hotel management system (PMS
application) is suitable for communicating with
the communication server.
Date, time
Connection to PMS system
established
A connection with a hotel management system
(PMS system) has now been successfully estab-
lished.
Date, time
Connection to PMS system
failed
An unsuccessful attempt was made to establish
a connection with a hotel management system
(PMS system).
Reason: 1: Call rejected, 2: Destination unob-
tainable, 3: Destination busy, 4: Connection
timeout, 5: Wrong address, 6: Unknown error
Error, date, time