Installation
97
Aastra 470 ab R3.0
syd-0337/1.5 – R3.0 – 05.2013
4. 2. 5 Desktop installation
For desktop installation simply place the Aastra 470 communication server on a
flat, level surface. Several communication servers can be stacked directly on top of
one another.
For the desktop installation of the mehreren communication server proceed as fol-
lows:
1. Affix the 4 rubber feet supplied to each of the corners of the communications
server’s housing base.
2. If necessary install the redundant fan unit (see "Fitting an additional fan",
page 98)
3. Connect the earthing (see "Connecting the earthing wire", page 101).
4. Always observe the location requirements set out in Tab. 37.
4. 2. 6 Rack-mounting
The rack mounting of the Aastra 470 communication server allows it to be installed
horizontally in a 19” rack. Be sure to observe the following:
• The communication server takes up the space of 2 height units (units) inside the
19” rack. (1 unit corresponds to 44.45 mm).
• Several communication servers can be stacked directly on top of one another. To
do so, make sure the rubber feet are removed first.
• With interface cards with more than 8 ports it is advisable to route the cabling
via an fan-out-panel (FOP) (1 height unit).