Operation and Maintenance
255
Aastra 470 ab R3.0
syd-0337/1.5 – R3.0 – 05.2013
System memory usage over
the critical range
Memory usage in the file system for a particular
purpose has exceeded a critical value
Purpose (file type ID):
0: File system, 1: Application, 2: Crash-Log,
3: Monitor-Log, 4: Announcement service,
5: Voice mail, 6: Music on hold, 7: Backup,
8: Hospitality/Accomodation, 9: User folder
File type ID, memory usage in
%, date, time
System Overload Network access attempted when all lines are
seized or the system is overloaded.
Route number, user number,
date, time
System phone back in service A system phone on the DSI bus is ready for
operation again.
Card number, port number,
user number, date, time
System phone out of service A system phone on the DSI bus is defective or
was disconnected.
Card number, port number,
user number, date, time
Temperature back in normal
range
Following overheating, the temperature inside
the communication server is back in the normal
operating range.
Card number, temperature,
date, time
Temporary activation expires
on
Reminder of the missing, definitive activation
licence following connection set-up with the
communication server.
Expiration date [DD.MM.YYYY],
date, time
Terminal power supply: Back
in normal range
The power supply to the terminals is back in the
normal rated output range following a slight,
preceding overflow.
Date, time
Terminal power supply:
Overload
Rated output slightly exceeded for > 4 s (see
also "Overload shutdown", page 91).
Date, time
Terminal power supply:
Shutdown
Rated output clearly exceeded for 4 s Date, time
Terminal power supply:
Switching back on
The power supply to the terminals was
switched back on after deactivation due to
overflow.
Date, time
The communication server
has been restarted
The communication server was restarted man-
ually or automatically due to an error.
Date, time
The licence limit for Aastra SIP
terminals has been reached
An Aastra SIP terminal is unable to register or
use the video functionality because there are
too few Aastra SIP Terminals or Aastra Video Ter-
minals licences available.
Parameter 1=1: Missing Aastra
SIP Terminals licence, parameter
2=1: Missing Aastra Video Ter-
minals licence, parameter 3=3:
Max. number of licences, date,
time
The licence limit for BluStar
clients has been reached
An BluStar was unable to register because there
are too few licences for this client type.
Parameter 1: 0 (not used)
Licence type: 0 and 1: (not used), 2: BluStar CTI,
3: BluStar softphone, 4: BluStar video option,
5: BluStar presence option, 6: BluStar Microsoft
Lync Plugin, 7: BluStar IBM Sametime Plugin
Parameter 1, licence type, total
purchased licences, date, time
The licence limit for CSTA ses-
sions has been reached
An application is unable to set up a CSTA ses-
sion to monitor/check a terminal because there
are too few CSTA Sessions licences available.
Max. number of licences, date,
time
Event / error message Trigger condition Details