Operation and Maintenance
257
Aastra 470 ab R3.0
syd-0337/1.5 – R3.0 – 05.2013
TLS certificate will expire soon A TLS certificate for an SIP node or SIP endpoint
is about to expire and needs to be renewed.
If the endpoint type is = 0 (Aastra), then is
parameter 2 = node ID.
If the endpoint type is = 1 (3rd party), then the
remaining parameter data contains the first
eleven characters of the certificate name.
Type of endpoint (0: Aastra,
1: 3rd party), node ID or certifi-
cate name, date, time
Too few FoIP channels Setting up a fax connection via T.38 failed
because no FoIP channel is available.
Available FoIP channels on
nodes
Too few licences for PMS inter-
face
Either the Hospitality PMS Interface licence is
missing or the number of Hospitality PMS
Rooms licences available is insufficient.
Number of licensed rooms,
number of configured rooms,
date, time
Too few VoIP channel licences Connection setup failed because the licence
limit for simultaneously active VoIP channels
has been reached.
No. of licensed VoIP channels,
Date, Time
Too few VoIP channels An user is trying to set up a connection that
requires one or more VoIP channels which are
currently not available.
Available VoIP channels on this
node, date, time
Too many error woth the
same ID
An unusual amount of errors (more than 50 per
hour) with the same error ID have occurred.
Error ID, date, time
Too many event messages Number of message types exceeds limit
entered in the table on:
"Synch. loss on BRI/PRI"
"Outgoing Call Rejected"
"No response from network"
Date, time
Too much user data System capacity exceeded Date, time
Total Synchronization loss Network synchronisation has failed on all BRI/
PRI interfaces
Date, time
Trial licence expired The duration for which a trial licence can be
used for a specific feature has expired and there
is no valid licence.
Licence ID, date, time
User does not answer No answer to incoming DDI call from user on S
bus or DSI
DDI No., date, time
User event message With *77[nnnn] from a terminal nnnn [0000...99999], user num-
ber, date, time
User memory usage is back
below the critical range
Memory usage in the file system for a particular
user has again exceeded a critical value
User number, memory usage in
%, date, time
Wake-up call unanswered The room wake-up call was not answered Room No., date, time
Wake-up order confirmed The room wake-up call has now been answered Room No., date, time
Event / error message Trigger condition Details

Table of Contents