69 XFC G4 2103335 Rev AB
Figure 52 XFC
G4
Static Pressure Input Line
Materials(not supplied)
Stainless steel tubing
Static pressure isolation/shut off valve
Tubing fittings
NOTICE-Equipment damage: A backup wrench should always be used when working with stainless steel tubing
and valves. This prevents the fitting from turning and/or putting tension on the stainless steel tubing.
4.8.2 Step-by-Step Instructions
Tools needed
-Combination wrench
-Tubing cutter
To install the static pressure input lines:
Install the static pressure isolation valve on the meter run.
Connect the static pressure tubing to the static pressure isolation valve and the flow computer static pressure input
port connection.
IMPORTANT NOTE: The valve to the flow computer fittings are not supplied with the flow computer.
Leak check all connections.