Service Management Tasks
Page 86 7210 SAS M Services Guide
Modifying SDPs
Note : SDPs are not supported by 7210 SAS-M devices configured in Access Uplink mode.
To access a specific SDP, you must specify the SDP ID. To display a list of SDPs, use the
show
service sdp
command. Enter the parameter, such as description, far-end, and lsp, and then enter the
new information.
NOTE: Once created, you cannot modify the SDP encapsulation type.
CLI Syntax: config>service# sdp sdp-id
Example
: config>service# sdp 79
config>service>sdp# description “Path-to-107”
config>service>sdp# shutdown
config>service>sdp# far-end “10.10.10.107”
config>service>sdp# path-mtu 1503
config>service>sdp# no shutdown