Virtual Private LAN Services
7210 SAS M Services Guide Page 349
Configuring AS Pseudo-wire in VPLS
Figure 57: Sample Topology-AS Pseudo-wire in VPLS
In Figure 57, Pseudo-wire is configured on MTU. A sample configuration on the MTU is listed 
below:
*A:MTU>config>service>vpls>endpoint# back 
*A:MTU>config>service>vpls# info 
----------------------------------------------
            send-flush-on-failure
            stp
                shutdown
            exit
            endpoint "vpls1" create
                description "vpls1_endpoint"
                revert-time 60
                ignore-standby-signaling
                no suppress-standby-signaling
                block-on-mesh-failure
            exit
            sap 1/1/3 create
            exit
            spoke-sdp 301:1 endpoint "vpls1" create
                stp
                    shutdown
                exit
                block-on-mesh-failure
            exit
            spoke-sdp 302:1 endpoint "vpls1" create
                stp
                    shutdown          
                exit
                block-on-mesh-failure
            exit
            no shutdown
----------------------------------------------
*A:MTU>config>service>vpls# 
 
-
-
PE-C MTU