The number of classification entries (TC) used is calculated, as follows:
(2 * 1)nc + (2 * 1)h1 + (2 * 1)ef + (2 * 1)h2 + (2 * 0)l1 + (2 * 2)af + (2 * 1)l2 + (2 * 1)be = 16
The number of meters (TP) used are: 5 ( Meters 1,2,3,9,12).
Example 7
network 2 create
description "network-policy 2"
scope template
ingress
default-action fc be profile out
meter 1 create
mode trtcm
adaptation-rule cir closest pir closest
rate cir 0 pir max
mbs default
cbs default
exit
meter 9 multipoint create
mode trtcm
adaptation-rule cir closest pir closest
rate cir 0 pir max
mbs default
cbs default
exit
network-policy 2 0 fc be profile out
network-policy 2 1 fc l2 profile in
network-policy 2 2 fc af profile out
network-policy 2 3 fc af profile in
network-policy 2 4 fc h2 profile in
network-policy 2 5 fc ef profile in
network-policy 2 6 fc h1 profile in
network-policy 2 7 fc nc profile in
exit
egress
no remarking
The number of classification entries (TC) used is: 18.
The number of meters (TP) used is: 2.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent 7210 SAS Series and is the answer not in the manual?

Alcatel-Lucent 7210 SAS Series Specifications

General IconGeneral
BrandAlcatel-Lucent
Model7210 SAS Series
CategorySwitch
LanguageEnglish

Related product manuals