Service Management Tasks
Page 148 7210 SAS D, E, K OS Quality of Service Guide
Example 8
network 8 create
description “network-policy-8”
ingress
default-action fc nc profile in
meter 1 create
exit
meter 2 create
exit
meter 3 create
exit
meter 4 create
exit
meter 5 create
exit
meter 7 multipoint create
exit
meter 8 multipoint create
exit
meter 9 multipoint create
exit
meter 12 multipoint create
exit
fc "af" create
meter 2
multicast-meter 12
exit
fc "ef" create
meter 4
multicast-meter 8
exit
fc "h2" create
exit
fc "l2" create
meter 3
multicast-meter 7
exit
fc "nc" create
meter 4
multicast-meter 8
exit
dot1p 1 fc l2 profile in
dot1p 3 fc af profile in
dot1p 5 fc ef profile in
dot1p 7 fc nc profile in
exit
egress
The number of classification entries (TC) used is calculated, as follows:
(2 * 2)nc + (2 * 0)h1 + (2 * 1)ef + (2 * 0)h2 + (2 * 0)l1 + (2 * 1)af + (2 * 1)l2 + (0 * 0)be =
10
The numbers of meters (TP) used is: 6 (Meters 2, 3, 4, 7, 8, 12).