Set the following items: These are settable only when Call. Proc. state is Stop.
Item Range Resolution Initial value
Paging Channel Walsh Code 1 to 7 1 1
Traffic Channel Walsh Code 8 to 31, 33 to 63 1 8
OCNS Channel Walsh Code 1 to 31, 33 to 63 1 63
SID 0 to 32767 1 7
Register SID 0 to 32767 1 12 Note 1
NID 0 to 65535 1 1
Register NID 0 to 65534 1 12 Note 1
BASE_ID 0 to 65535 1 39
Slot Cycle Index 0 to 7 1 0 Note 2
Default ESN 00000000 (hex) to FFFFFFFF (hex) 1 FFFFFFFF (hex)
IDT (Default MSID) MSIN 1 34-bit MIN Note 3
MSID (Default MSID) See the table below. 1
See the table below.
Note 4
ACCH DCC 0 to 2 1 0
SCC (SAT Color Code) SAT1 : 5970 Hz (None) SAT2
SAT2 : 6000 Hz
SAT3 : 6030 Hz
DSAT Sequence 0 (2556CB) to 6 (2969AB) 1 0 (2556CB)
AF Osc. output to FM Mod., Off (None) FM Mod.
Signal Tone, Noise (ITU-T G.227), (None) Tone
Noise (White)
Frequency 20 Hz to 20 kHz 0.1 Hz 1004.0 Hz
Deviation 0 to 40 kHz 10 Hz 8.00 kHz
Correspondence between IDT and MSID (Decimal notation)
IDT MSIN
Initial value [DEC][------0000000000]
Minimum value [DEC][------0000000000]
Maximum value [DEC][------9999999999]
Correspondence between IDT and MSID (Hex-decimal notation)
IDT MSIN
Initial value [HEX][------3E7F9EBE7]
Minimum value [HEX][------0000000000]
Maximum value [HEX][------3FFFFFFFFFF]
Note:
Setting is enabled only when the Call Processing state is Stop.