4-137
4.3 CDMA Transmitter and Receiver Test --- TX and RX Tester Mode
• Main function key: (None)
• Function keys:
[Default] F9: Sets each item to the initial value.
[Back Screen] F12: Displays the previous screen (Setup Common Parameter screen).
Note 1:
<Register SID, Register NID>
Register SID and Register NID are set for Forced Registration. Their values
should be different from SID and NID, respectively.
Note 2:
<Slot Cycle Index>
This is a parameter to set a periodic time interval for monitoring the paging
channel.
Note 3:
<IDT >
This is a parameter to select the input type of the mobile station identification
number.
Range: IMSI (International Mobile Station Identification number)
MSIN (Mobile Station Identification number)
Note 4:
<MSID>
This is a parameter to enter the mobile station identification number.
When connecting the mobile station; the entered MSID enables to execute the
“NW Originate” in “Idle” state of Call Processing, to shorten the time for be-
coming the Loop Back state. The “Registration” is not required.
When the “Registration” is performed with the entered MSID, the mobile sta-
tion identification number is obtained and displayed.