EasyManua.ls Logo

APP APP-601 - Maintaining the APP Recorder

APP APP-601
146 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Using the APP Recorder 6-34
6.10.6 Turning On or Off Dial-up Networking
If you have configured dial-up networking, you can manually turn it on or off as necessary.
See Setting Up Dial-up Networking for instructions on setting up dial-up networking
To Turn On or Off Dial-up Networking
In the APP Recorder window, from the Connect menu, click Dial-up Networking.
If the menu option says, Off, then clicking this option immediately turns on dial-up
networking.
If the menu option says, On, then clicking this option immediately turns off dial-up
networking.
6.11 Maintaining the APP Recorder
You can perform the following maintenance tasks for the APP Recorder:
View the trace files
Run a diagnostic test
View all SER abnormal or stopped channels
Perform a test run
View the list of “ON” alarms
Reset the FID
Reinitialize the APP Recorder
Restart APP Recorder
Reboot the APP Recorder
Reserve the Memory and defrag the data drive
6.11.1 Viewing Trace Files
You can use trace files to help during troubleshooting. There is a separate trace file for the APP Recorder
and the APP Driver.
Trace files include:
Tracexxx.wri Driver Trace File
CTracexxx.wri Connection Trace File
RTracexxx.wri Recorder Trace File
ATracexxx.yyy All Trace File
Note: xxx is recorder number and yyy is a sequence number
Each trace file lists the major processes carried out by its respective program, either the APP Recorder or
the APP Driver. When a trace file grows to approximately 500 Kbytes, it will automatically be closed and
given an extension an incremented extension (for example, .001, .002, and so on.) A new trace file will be
created.
There is also an All Trace (ATrace) file available. The ATrace is intended for use with software to parse
the ATrace log for specific trace information. The ATrace is not simply a consolidation of the Recorder and
Driver trace files. The ATrace includes additional trace information from: Recorder, Driver, PMU, DNP3,
Modbus, IRIG-B and is intended for diagnostics and correlation of log entries.
The Recorder, Driver trace and ATrace files are stored in the C:\APP Recorder\Setup directory.

Table of Contents