Using the APP Recorder 6-20
10. No Trigger check box causes the report to exclude Analog Trigger faults from the report. An
Event Trigger will still display if an Event Channel is set up, and an Event Channel caused the
Trigger or an Event Channel changed state while the record was being created.
11. In the Panel Size box, enter the percentage of space the event and analog trigger lines will use at
the bottom of a printed page.
12. In the Font Size Global Control box, enter the font size to be used for the title of the waveform
pages and any annotations that may have been added. You cannot change the font on the Fault
Summary Report.
13. In the Font Size Title Control box, enter the font size for the title that appears at the top of each
waveform or oscillogram page.
14. In the Annotation Text Size box, enter the font size for any annotations that are added to a
waveform or oscillogram page.
15. Click OK.
6.7.10 Configuring Email Settings
You can configure the APP Recorder to automatically email fault summary information to the master
station. When the APP Recorder sends an email, it sends a plain text e-mail message containing a summary
of a fault. The following information is included in the report:
Recorder ID
Fault ID number
Fault date and time
Fault duration
Fault location report (if calculable)
Note: The Recorder must have an SMTP/POP3 email account and connectivity in order for the
Email feature to work properly.
To Configure Email Settings
1. Open the Recorder Configuration window and open the Automatic Tasks tab. See Figure 27.
2. Select the Email check box.
Note: If the Email check box is not selected, the APP Recorder will not automatically send
emails with fault summary information.