Installation Overview 3-6
*WARNING*
Ensure that your power source wires are not live (turned off or
disconnected). Follow OSHA power safety lock out procedures.
Ensure that your source can provide sufficient current to the
recording system. Ensure that your power source is fused and
properly earth grounded.
20. Connect power from your source to the main or 1
st
Data chassis power supply board (terminals
1&2). Use insulated #6 ring terminals
*WARNING*
Reference the drawings provided with the system.
21. If using an APP-501 Computer Control chassis, open the hinged front door, pull out the computer,
and flip up the monitor. If you purchased the optional APP-601 Monitor and Keyboard chassis
(for the APP-601 Computer Control Chassis), open the hinged front panel door and pull out the
monitor and keyboard.
22. Carefully and with great prior inspection and thought, turn on your power source.
23. Carefully turn on the power switches located at the rear of the Data chassis.
24. If a proper turn on occurs you should see the following:
Computer startup
APP Recorder program begins
All Data chassis front panel POWER LED illuminate green, the ON LINE LED illuminate
green, the 1PPS LED illuminate green, and only if the continuous recording is enabled the
CONT RECORD LED illuminate amber (yellow).
25. If the system has not powered up correctly, please recheck your wiring and review the wiring
prints that shipped with the recorder.
26. Please call the factory for any required assistance (317) 536-5300.