4-26
Instruments and Programming
X6 - P/N 6525032M1
Errors
If no alarms is displayed and the system detects one at least, the high priority pop-up as shown under is shown to indicate
the total number of alarms.
Number of present/detected alarms
Indicated 4 alarms present/number of pages
The first page shows the number of present alarms, that are shown in the fol-
lowing pages.
The main display shows all errors in the system (errors of the instrument cluster + other errors of the electronic controllers).
If there are no errors in the system, the menu is disabled.
Press Enter to go to the pages that show the enabled alarms in the following format.
ECU - Control unit that detects the error
SPN and FMI are the values that must be communicated to the service centre to identify the
problem.
2/4 indicates: number of displayed alarm/total number of displayed alarms.
Press Esc to leave alarm display and return to the main page.
If the alarm lists change during these displays, the system updates the list, but the screen shows the same alarm.