5-38
Operation
X6 - P/N 6525032M1
Engine set point (if equipped) - Fig.
MC1
By the Engine Set Point function it is possible to set and
keep a constant engine RPM rate, regardless of load
variations.
When this function is active, also the RPM rate of the
independent rear PTO remains constant.
NOTE: This function lets not maintain a constant ground
speed (e.g. as with cruise control), but keeps a constant
engine RPM rate depending on the work load, while the
ground speed will depend on the range/Powershift gear
ratio then engaged.
The activation of the Engine Set Point function is con-
firmed by the lighting of the lamp in the button itself and
by the display of the icon in the instrument cluster:
To memorize the required RPM:
• Use the throttle pedal and/or the hand throttle to reach
the required RPM rate of the engine.
• Press the button (1) and hold for at least 1 second
(long pressure) to memorize the actual RPM rate. The
successful memorization is confirmed by:
− the lighting of the lamp on the button
− the display of a pop-up that reports the memorized
engine RPM rate and of the icon in the place
or the gear in the “Transmission” area of the display
(see chapter "Constant engine RPM rate" in section
4 of this manual for further details on the screen
masks and indications).
Activation/deactivation of Engine Set Point
After memorizing the engine RPM rate, the Engine Set
Point function can be activated or deactivated by a brief
pressure on the button (1).
If the engine is not stopped, the sequence of deactiva-
tion/activation of the Engine Set Point function does not
deletes the RPM rate previously memorized.
If the function is active - lamp lit in the button (1) - to
memorize a new engine RPM rate proceed as follows:
− Deactivate the function.
− Bring the engine RPM rate to the new required level.
− Press the button (1) and hold for at least 1 second (long
pressure) to memorize the new RPM rate.
NOTE: When the tractor engine is stopped (Key Off),
the value memorized in the Engine Set Point function is
deleted. The next time the tractor engine is started, the
required RPM rate must be memorized over again.
Engine set point button (1):
• Longer pressure: memorization of the set RPM rate
• short pressure: function activated/deactivated
NOTE: When the Engine Set Point function is active, the
engine RPM rate can be increased using the throttle pedal
or the manual throttle.
If the function is kept active, the RPM rate cannot decrease
lower than the set value using the throttle pedal or the
manual throttle; to decrease, the Engine Set Point must