Instruments and Programming
4-43
4
P/N 6525032M1 - X6
Work hours management
The display shows the actual hours worked by the tractor.
The value on the hour counter cannot be changed or
deleted.
The value displayed ranges from 0.0 to 999999.9. When
the value 999999.9 is reached, the hour counter stops.
clock
actual hours
worked by the
tractor
Alarms displayed on the instrument
cluster
The instrument cluster stores and displays all errors gener-
ated in various components and systems of the tractor,
Alarms of instrument cluster
Errors can be displayed in two ways:
1. Directly, the display shows actual errors.
2. Through instruments available to personnel of the Argo
Tractors Dealer.
Each alarm is identified by the electronic module that
generated it (IC, ECU, TC or ICH), by the SPN code plus
FMI code. The electronic module that generated the alarm
and the codes SPN and FMI displayed by the instrument
cluster should be communicated to the service personnel
for a quick solution to the problem.
General alarms (yellow)
The indicator light may be in one of the following condi-
tions:
- Off
- Steady on
- Blinking (0.5” on / 0.5” off)
Engine alarms (yellow)
The indicator light may be in one of the following condi-
tions:
- Off
- Steady on
- Blinking (0.5” on / 0.5” off)
- Fast flashing (0.25” on / 0.25” off)
General alarms (red)
The indicator light may be in one of the following condi-
tions:
- Off
- Steady on
- Blinking (0.5” on / 0.5” off)
Error displaying
Each error is displayed for minimum 5".
For error displaying see “Errors” on page 4-26
CAUTION
If signals of indicator lights and messages are ignored,
the tractor is exposed to serious damages.