SmartROC D65 T4F 9 Angle instruments
127 No: 713944459.6 en
To return to F4, press ESC twice and the selected angles from ROC Manager are presen-
ted together with bars on the side with drill bit location in relation to the selected coordin-
ates for the hole in question.
Reset the depth meter in the normal way. Now hole length is presented for the selected fi-
nal plan in the local coordinate system. Start drilling in the normal way. The rig will stop
drilling when the correct final plan is attained.
After drilling one hole, select the next one and repeat as above.
If further holes need to be added:
n Position the drill bit in the intended location for the hole.
n Move the cursor to the combo box Hole action and select Add, confirm with Enter.
n Confirm with Execute if other factors for the hole correspond.
!
NOTE: When the drill plan has been drilled everything must be saved for retrieval in
the event of changes to the original.
n Select Save in the combo box entitled Drillplan action: and confirm with Enter.
!
NOTE: Notice! If there is no USB stick in the USB socket then nothing is saved.
Quality log
In addition, save a quality log for retrieval with all facts on the completed drill plan.
n Select Logging