Pset STwrench User Guide
92 (326) 9836 4134 01 Edition 2.9
6.3 Timeout
Ratchet time
Applied when the torque goes below the cycle start but has not yet reached the 3
rd
Percentage value (see LED settings). This allows the operator to release the torque for a
while and recharge during the tightening operation; the default value is 5 seconds.
Minimum value: 0.1 sec
Maximum angle for
result search
If the Measure Torque at is set to Angle Peak, the result is taken at the maximum
torque in the last angle degrees defined here, starting from the angle peak measured.
The maximum value is 4°.
It is active only for the Torque (monitor) / Angle (Control) control strategy. See the
Torque (Monitor) / Angle (Control) chapter for more information.