Version 7.2 1053 Mediant 1000B Gateway & E-SBC
User's Manual 62. Configuration Parameters Reference
Parameter Description
[CallWaitingPerPort]
CallWaitingPerPort_IsEnabled, CallWaitingPerPort_Module,
CallWaitingPerPort_Port;
[\CallWaitingPerPort]
For example:
CallWaitingPerPort 0 = 0,1,1; (call waiting disabled for Port 1 of
Module 1)
CallWaitingPerPort 1 = 1,1,2; (call waiting enabled for Port 2 of
Module 1)
Note:
ï‚§ The parameter is applicable only to FXS ports.
ï‚§ For a detailed description of the table, see Configuring Call
Waiting on page 587.
Number of Call Waiting
Indications
configure voip > gateway dtmf-
supp-service supp-service-
settings > nb-of-cw-ind
[NumberOfWaitingIndications]
Defines the number of call waiting indications that are played to
the called telephone that is connected to the device for Call
Waiting.
The valid range is 1 to 100 indications. The default is 2.
Note: The parameter is applicable only to FXS ports.
Time Between Call Waiting
Indications
configure voip > gateway dtmf-
supp-service supp-service-
settings > time-between-cw
[TimeBetweenWaitingIndications]
Defines the time (in seconds) between consecutive call waiting
indications for call waiting.
The valid range is 1 to 100. The default is 10.
Note: The parameter is applicable only to FXS ports.
Time Before Waiting Indications
configure voip > gateway dtmf-
supp-service supp-service-
settings > time-b4-cw-ind
[TimeBeforeWaitingIndications]
Defines the interval (in seconds) before a call waiting indication is
played to the port that is currently in a call.
The valid range is 0 to 100. The default time is 0 seconds.
Note: The parameter is applicable only to FXS ports.
Waiting Beep Duration
configure voip > gateway dtmf-
supp-service supp-service-
settings > waiting-beep-dur
[WaitingBeepDuration]
Defines the duration (in msec) of call waiting indications that are
played to the port that is receiving the call.
The valid range is 100 to 65535. The default is 300.
Note: The parameter is applicable only to FXS ports.
[FirstCallWaitingToneID] Defines the index of the first Call Waiting Tone in the CPT file.
This feature enables the called party to distinguish between
different call origins (e.g., external versus internal calls).
There are three ways to use the distinctive call waiting tones:
ï‚§ Playing the call waiting tone according to the SIP Alert-Info
header in the received 180 Ringing SIP response. The value of
the Alert-Info header is added to the value of the
FirstCallWaitingToneID parameter.
ï‚§ Playing the call waiting tone according to PriorityIndex in the
ToneIndex table parameter.
ï‚§ Playing the call waiting tone according to the parameter
“CallWaitingTone#' of a SIP INFO message.
The device plays the tone received in the 'play tone
CallWaitingTone#' parameter of an INFO message plus the value

Table of Contents

Other manuals for AudioCodes MediaPack MP-11 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-11 Series and is the answer not in the manual?

AudioCodes MediaPack MP-11 Series Specifications

General IconGeneral
BrandAudioCodes
ModelMediaPack MP-11 Series
CategoryGateway
LanguageEnglish

Related product manuals