Version 7.2 917 Mediant 1000B Gateway & E-SBC
User's Manual 59. Testing SIP Signaling Calls
Batch Test Call Scenario: This example describes the configuration of a batch test
call setup for scheduled and continuous call testing of multiple endpoints. The test call
is done between two AudioCodes devices - Device A and Device B - with simulated
test endpoints. This eliminates the need for phone users, who would otherwise need
to answer and end calls many times for batch testing. The calls are initiated from
Device A, where Device B serves as the remote answering endpoint.
Figure 59-9: Batch Test Call Example
Test Call Rules table configuration at Device A:
Endpoint URI: "101"
Called URI: "201"
Route By: Dest Address
Destination Address: "10.13.4.12"
SIP Interface: SIPInterface_0
Call Party: Caller
Maximum Channels for Session: "3" (configures three endpoints - "101",
"102" and "103)
Call Duration: "5" (seconds)
Calls per Sec: "1"
Test Mode: Continuous
Test Duration: "3" (minutes)
Schedule Interval: "180" (minutes)
Test Call Rules table configuration at Device B:
Endpoint URI: "201"
Maximum Channels for Session: "3" (configures three endpoints - "201",
"202" and "203)

Table of Contents

Other manuals for AudioCodes MediaPack MP-11 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-11 Series and is the answer not in the manual?

AudioCodes MediaPack MP-11 Series Specifications

General IconGeneral
BrandAudioCodes
ModelMediaPack MP-11 Series
CategoryGateway
LanguageEnglish

Related product manuals