Job Aid: Replacing the SAMP power supply
136 Job Aids for Field Replacements (FRUs) for the Avaya S8500 Server
Replacing the SAMP power supply from the S8500C
To replace the SAMP power supply (RoHS version, Material ID 700405004):
1. Connect the RJ11 end of the new power supply to the connector on the rear panel of the
S8500B server.
2. Connect the grounded, 110 VAC plug to the new transformer.
3. Connect the plug to the power source.
Replacing the SAMP power supply on the S8500B server
This simple procedure requires two steps:
l Removing the old power supply from the S8500B
l Replacing the power supply from the S8500B
!
Important:
Important: Ensure that the replacement power supply is Material ID 700340110 only. You
cannot interchange SAMP power supplies.
Removing the old power supply from the S8500B
To remove the old or defective SAMP power supply from the S8500B server you do not need to
power-down the server:
1. Remove the plug from the power source.
2. Remove the power connection from the SAMP board’s RJ11 connector on the rear panel of
the S8500B server.
3. Do not re-use any part of the power supply.