Replacing the S8500/B/C server
13 Disconnect the cable from
the dual NIC (if used)
Disconnect and label the cable from the Ethernet port
on the dual NIC (if used).
14 Disconnect the crossover
cable
Disconnect the crossover cable from the services port
on the back of the server.
Initial tasks for replacing an S8500/B/C server reusing the original
hard drive (continued)
9
Task Description
3 of 3
Tasks for replacing an S8500/B/C server
9
Task Description
1 Shut down the server If the hard drive is functional, under Server, click
Shutdown This Server then unclick Restart Server
after Shutdown. Press the power-control button on
the front of the server. The internal fan shuts off.
Caution: Do not unplug a functioning server without
stopping all processes first. Failure to do this corrupts
the hard drive. This is especially important if reusing
the hard drive.
Caution: Do not hold down the power button for more
than a split second. Holding the button down too long
causes the server to reboot.
2 Unplug the server Once the server is completely shut down, unplug the
power cords from the server and RSA/SAMP.
Caution: Do not unplug a functioning server without
stopping all processes first. Failure to do this corrupts
the hard drive. This is especially important if reusing
the hard drive.
Disconnect and label the LAN connections from the
Ethernet ports on the RSA/SAMP and dual NIC (if
used).
Disconnect all attached devices, including the laptop,
both modems, and the external flashcard reader (if
used).
1 of 3