7-62
Chapter 7. PARAMETER SETUP
C
9
3
(CPL communications port selection)
•Whensetto0,CPLcommunicationsfromtheloaderjackisnot
possible.Inthiscase,CPLcommunicationsispossiblefromthe
addonterminalundersetup
C84
and
C85
communications
conditionsifthecontrollermodelsupportsCPLcommunications.
•Whensetto1to15,CPLcommunicationsfromtheloaderjackis
notpossible,andthe
C93
settingbecomestheCPLcommunica-
tionsaddress.
Communicationsconditionsarealso4800bps,evenparityand1
stopbit.
Inthiscase,CPLcommunicationsisnotpossiblefromtheaddon
terminalevenifthecontrollermodelsupportsCPLcommunica-
tions.
•UsethespecialcabletoconnecttheRS-232Cportonthepersonal
computerandtheloaderjackontheequipment.
•Whenthesetup
C00
(ROMrevision)settingindicationis0or1,
thesetup
C93
settingindicationcannotbesetat“---”.
Also,communicationsfromtheloaderjackisnotpossible.
•FordetailsaboutCPLcommunications,refertoDIGITRONIK CPL
Communications “DCP30”, Manual No. CP-UM-1760E.