7. Advanced
How to reset the lamp runtime?
1. Press MENU to activate the tool bar
2. Press to select the Lamps item
3. Press to pull down the Lam ps menu
4. Use or to select Reset Runtime
5. Press to open the Res et Runtime menu
6. Use or to select the lamps to be reset
Image 7-138
7. Press ENTER
A dialog box is displayed
Image 7-139
8. Use or , the numeric keys on the remote, or the keypad to change the serial number of the lamp (serial number 0000000 will
not be accepted).
9. Select Accept to reset the lamp runtime and to conrm the serial number of the new lamp
7.7.7 Clear lamp error
Lamp error
When a failure of one of the lamps has occurred, a lamp logo is displayed in the left corner of the screen. This logo will thus always
inform the user on a previous lamp error.
Once the error has been solved or/and the lamp has been replaced one can remove (clear) the lamp error.
If the error has been cleared without solving the lamp problem the logo will be shown at next lamp startup (projector startup for
example)
A lamp failing to startup will be noticed by a low light output of the projector since the projector goes in single
lamp mode.
In case of a lamp error contact the lo
cal Barco authorized technician
R59770324 SIM 5W 22/12/2011 125