Lens Zoom
Left
Right Total horizontal
shift
Up Down
Total vertical shift
CLD 1.2-1.6:1
TP
85% 20% 105% 115% 20% 135%
CLD 1.2-1.6:1
WA
85% 20% 105% 115% 20% 135%
CLD 1.2-1.6:1 SF
TP
85% 20% 105% 115% 20% 135%
CLD 1.2-1.6:1 SF
WA
85% 20% 105% 115% 20% 135%
CLD 1.6-2.4:1
TP
85% 20% 105% 115% 20% 135%
CLD 1.6-2.4:1
WA
85% 20% 105% 115% 20% 135%
CLD 2.4-4.3:1
TP
85% 20% 105% 115% 20% 135%
CLD 2.4-4.3:1
WA
85% 20% 105% 115% 20% 135%
QCLD 0.85:1
TP
0% 0% 0% 0% 0% 0%
QCLD 0.85:1 SF
TP
0% 0% 0% 0% 0% 0%
QCLD 1.1-1.3:1
TP
85% 20% 105% 115% 20% 135%
QCLD 1.1-1.3:1
WA
65% 20% 85% 115% 20% 135%
QCLD 1.1-1.3:1 SF
TP
85% 20% 105% 115% 20% 135%
QCLD 1.1-1.3:1 SF
WA
65% 20% 85% 115% 20% 135%
Table 4 -3
Maximum shift measured for different lenses on this projector
On-axis image (0 % shift
vertically and horizontally)
Off-axis image
d
h
D
h
D
v
D
v
(a) horizontal shift (b) vertical shift
Image 4-8
%off-axis: Deningthedistancetomeasurethe%off-axis
Up
RightLeft
Down
Image 4-9
Safe shift range based on the maximum up/down, left/right directions