7. Advanced
Image 7-164
The common color values are automatically calculated based on the measured values of both projectors and these calculated
values are put in the Desired values of both projectors. Both projectors will now operate within the same color gamut.
Link Set can only be performed if the linked CLO has been enabled, see Linked Projectors.
7.9.6.4.4 Infitec common color values
Manually : Calculating the Infitec common color values
1. Calculate the common values and fill them in the Desired values of both projectors.
Both projectors will now operate within the same color gamut.
Automatically : Link Set
1. Start up the Linked Projector menu of the Master projector
2. In the Linked Projector menu press the Link Infitec Set button
The common color values are automatically calculated based on the measured values of both projectors and these calculated
values are put in the Desired values of both projectors. Both projectors will now operate within the same color gamut.
142
R59770324 SIM 5W 22/12/2011
Downloaded From projector-manual.com Barco Manuals