11‐10
Icon Parameter
Function/Action
Range Of
Value
Default
Value
29
WS System
Sets WS System Active.
0 : OFF
1 : ON
0 - 1 0
30
Clamp Frame
Not Used
------- -----
31
Warm Up
Speed
Not Used
------- -----
32
Warm Up End
Not Used
------- -----
33
Frame Option
Sets the gain parameter automatically
0: Portal Frame
1: Spider Frame
2: One Touch Frame
Note:
*This function can only be activated with m/c
equipped with AC Servo Motors for V/H axis.
*Parameter used if m/c encounters distortion
problem while running when using one of the
inner frames listed due to pantograph load.
*Set to 1 and press the DRIVE button, rewrites AC
servo motor parameter to G3 from G2
automatically.
*Set to 2, and press the DRIVE button, rewrites AC
servo motor parameter to G4 from G2
automatically.
0 - 2 0
34
Sequin size
L1
Sets the Sequin Size Change on Left side
0-50
0