EasyManua.ls Logo

BIOPAC Systems MP36 - EL506; EL507; EL508; EL509

BIOPAC Systems MP36
157 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
info@biopac.com
support@biopac.com
www.biopac.com
BIOPAC Hardware | EL500 SERIES | Page 2 - 3 Updated: 11.4.2013
Part Ag-AgCl Adhesive/Disposable Electrode Type
EL506
Alternative
for band
electrodes
This unique disposable strip electrode is designed for bioimpedance applications. The electrode is
silver laminated on medical grade cloth, with industry-standard medical grade adhesive, medium
tackiness. The silver-silver chloride (Ag-AgCl) electrode provides accurate and clear transmission
of surface biopotentials and is latex free.
Strip length: 254mm
Conductive element width: 6.35mm
Adhesive width: 23.5mm
Advantages of the Strip Electrode
:
Combines the convenience of standard snap (spot) electrodes with the signal to noise,
equipotential and current diffusion performance of band electrodes
Less obtrusive than band electrodes--easier for subjects to move and breathe
Ergonomic advantages of snap (spot) electrodes
Diffuses currents similarly to band electrodes (reduces current density)
Provides voltage measurements through a well-defined equipotential plane
Adjustable size—cut the 25cm strip to the desired size without affecting signal transmission
Snap lead connection
Peel-and-stick convenience
Disposable
EL507
Designed for electrodermal activity studies and are pre-gelled with isotonic gel. The latex-free,
MRI-compatible electrodes conform and adhere well.
Wet Gel: 0.5% Chloride Salt
Contact area: 1 cm
Size: 2.5 cm x 4.5 cm
Snap: Stainless Steel
Backing: Foam
EL508
These disposable, radiotranslucent electrodes are pre-gelled.
Use with LEAD108. (See MRI use information for EL508 and EL509 below.)
EL509
These disposable, radiotranslucent dry electrodes have no shelf-life limitation and are ideal for
EDA/GSR applications. Use with LEAD108 and electrode gel—GEL101 recommended for
EDA/GSR.
To add gel:
1. Fill back cavity (adhesive side) with gel.
2. Add a drop of gel to the sponge pad.
3. Place the sponge pad into the cavity.
4. Press firmly to clear air pockets.
Circular contact area diameter: 1 cm
Backing: 25 mm x 44 mm
MRI Use: MR Conditional
Condition:
Carbon-filled plastic snap will not interfere with imaging; tested 3T-9T.
EL508/509 Components: Substrate: Tape with medical grade adhesive, Label: Bi-Oriented
Polypropylene (BOPP) or Vinyl, Stud: 40% Carbon-filled ABS plastic,
Eyelet: 20% glass-filled ABS plastic coated with Ag/AgCi, Reticulated
foam: Polyester-polyurethane, Gel: 10% chloride-liquid gel (EL508)