www.biopac.com
BIOPAC Hardware | AFT Series | Page 2 - 7 Updated: 12.3.2013
MOUTHPIECES
MRI Use: MR Safe
AFT Mouthpiece Components: Polyethylene EVA Copolymer, Thermoplastic Rubber,
Polycarbonate Plastic
AFT2 Disposable Mouthpiece Available in Packs of 10 or 250
22 mm OD; connects to the SS11LA or TSD117 via the AFT1.
AFT8 Autoclavable Mouthpiece Available in Packs of 1 or 10
30 mm ID; interfaces with the SS11LA or TSD117 and reduces the cost of disposable parts.
RX117 Replacement Sterilizable Airflow Head: 22 mm ID/30 mm OD; autoclavable transducer
head for the TSD117; can be used with the AFT8 to reduce the cost of disposable items.
AFT9 Reusable Mouthpiece Available in Packs of 1 or 10
35 mm ID; designed to connect to the TSD107B or other 35 mm breathing circuits with the AFT7 via
the AFT4. (Also connects to the AFT21 Non-rebreathing T Valve.)
NOSECLIP
MRI Use: MR Safe
AFT Noseclip Components: Thermoplastic Rubber, Polyvinyl Chloride (PVC) Plastic,
Polyurethane Foam Plastic
AFT3 Disposable Noseclip Available in Packs of 10 or 250
Gently squeezes the nostrils shut while using the SS11LA or TSD117 Airflow Transducer.
CALIBRATION SYRINGES
AFT6A Calibration Syringe
0.6 liter calibration syringe. See also: AFT26 2.0 liter Calibration Syringe
AFT26 Calibration Syringe (2.0 liter)
The AFT26 is a 2.0 Liter Calibration Syringe for the
SS11LA or TSD117 Airflow Transducer. The AFT26
Calibration Syringe is certified to have a 2-liter volume that
meets or exceeds an accuracy ± 1% of the total
displacement volume. The increased size and accuracy of
this 2.0 liter calibration syringe provide a wider calibration
range than the AFT6A for advanced studies. A coupler is included and can be reordered as AFT11I if it
is inadvertently discarded when an airflow accessory is removed.
TUBING FOR AIRFLOW
MRI Use: MR Safe
AFT7/7L/12 Tubing Components: Polyethylene EVA Copolymer
AFT7 Smooth Bore Tubing
1 m length, 35 mm ID; connects to the TSD107B, AFT4, or other 35 mm breathing circuits. See also:
AFT part guide for additional applications.
AFT7L Smooth Bore Tubing
3 m length, 35 mm ID; connects to the TSD107B, AFT4, or other 35 mm breathing circuits. See also:
AFT part guide for additional applications.
AFT12 Tubing (22mm)
Smooth bore tubing for use in 22mm breathing circuits. (1.8 meter length, 22 mm ID)