BIOPAC Hardware | Electrode Accessories | Page 2 - 3 Updated: 10.29.2013
GEL104 Electrode Gel - salt free - 250 g (8.5 oz). SPECTRA 360® electrode gel.The only salt-free
and chloride-free electrically conductive gel, recommended for all electromedical procedures.
Salt-free characteristics make it particularly suitable for long-term applications. Spectra 360
differs significantly from all other electrically conductive media...it works by wetting the
skin, thereby reducing skin resistance.
Salt-free, no sodium ion transfer
Non-irritating, hypoallergenic, bacteriostatic
Product of choice for conductive rubber/carbon electrodes
Product of choice for ECG and TENS
Non-gritty STAY-WET® formula allows for prolonged use without re-
application
MRI Use: MR Conditional
Condition: Max MR field strength 3T
GEL104 Salt-Free Components:
Water, Propylene Glycol, Mineral Oil, Glyceryl Monostearate, Polyoxyethelene Stearate,
Stearyl Alcohol, Methylparaben, Butylparaben, Propyl Paraben
GEL102 Ten20 Conductive Gel 114 g (~4 ounces). This gel is abrasive and should be used with care
not to overabrade the skin. It is not recommended for use with current inducing electrodes,
such as defibrillator or neuro-stimulating equipment. Not to be used on patients with a history
of skin allergies to cosmetics and lotions. Topical use only.
ECG:Apply gel to entire electrode site with gauze pad. Rub into skin lightly. Rub off
excess with clean gauze pad. Apply proper electrode gel and electrode.
EEG:Apply gel to electrode site on scalp with cotton swab. Rub lightly. Apply electrode
paste and electrode over the gel. Wash skin promptly after use.
GEL103 Tensive Adhesive Gel, 33 ml. Conductive adhesive gel. This safe, non-flammable, odorless
gel is recommended for TENS, EMG, EEG, and similar protocols.
Eliminates tape and tape irritation
Conductive immediately, no need to wait
Non-flammable, no solvent odor
Best adhesive gel available
Hypoallergenic, bacteriostatic, non-irritating
Water soluble, easily removed with water
Coban Wrap
Self-adhesive Coban™ wrap can be used to hold electrodes, VMG transducers and fNIR sensors on a subject.
4 inch x 5 y
ard (fully stretched) (100 mm x 4.5 m)
Latex free self-adherent wrap