71
Engine Management Module (EMM)
Diagnostic Software Functions
4
Dynamic Information
Dynamic information is viewed while the outboard
is running. Changes in data, such as voltages or
temperatures, are shown as they happen.
Occurred Fault Codes
Service codes are saved if an abnormal condition
occurs while the outboard is running.
The Occurred Faults screen of the diagnostics
software shows the code number, the number of
times the event occurred, and operating hours of
first and last occurrences.
Active Faults
An active fault is a service code that currently
exists. Active faults become occurred faults only if
the outboard is running.
Historical Faults
The Historical Faults screen keeps a history of all
previously saved codes, including code number,
the number of times the event occurred, and oper-
ating hours of the last occurrence.
Historical faults cannot be erased.
Static Tests
Static Tests allow diagnostic testing of system
components while the outboard is NOT running.
Monitor Screen
008566
Occurred Faults Review Screen
008584
Active Faults Review Screen
008585
Static Tests Screen
008569A