ICEfx™ Cryoablation System
User Manual
Only

Table of Contents

Questions and Answers

  • M
    mclaughlinbrianSep 23, 2025
    What to do if a gauge or a gas supply line is damaged on BTG ICEfx Medical Equipment?
    • G
      gonzalesmichaelSep 23, 2025
      Do not use any damaged product. Contact Galil Medical Customer Service for new accessories.
  • T
    tiffanymannAug 25, 2025
    What to do if USB flash drive is not recognized by BTG ICEfx Medical Equipment?
    • S
      Shannon JohnsonAug 25, 2025
      Remove the USB flash drive from the USB port on the Console, wait a few seconds, and then reconnect it. If the problem continues, try using a different Galil Medical supplied USB flash drive. If still not recognized, replace the USB flash drive with a new Galil Medical supplied one.
  • M
    Miranda FigueroaAug 25, 2025
    Why is the gas pressure too low on the Gas Indicator of BTG Medical Equipment?
    • A
      andrew63Aug 26, 2025
      Make sure the Argon Shutoff Valve is open. Verify that the argon cylinder valve is sufficiently opened to allow gas flow; if needed, open the valve approximately another half turn. Check that the cylinder contains sufficient pressure using the gauge on the cylinder, and replace the cylinder if necessary.
  • D
    Dean SteeleAug 27, 2025
    What to do if BTG Medical Equipment touch screen does not respond?
    • C
      Carol CainAug 27, 2025
      Turn OFF and restart the system using the power control switch on the rear of the system.
  • D
    danielsnyderAug 27, 2025
    What to do if needle is not freezing during Needle Integrity and Functionality Test on BTG Medical Equipment?
    • G
      gonzaleztracyAug 27, 2025
      Ensure the gas cylinder valve is open by turning it counterclockwise to allow sufficient gas flow, and verify that appropriate pressure is displayed on the Gas Indicator. If the needle might be clogged, try the test again. If the needle still does not freeze, stop all activity on the channel, disconnect the needle, move it to a different channel, and run the test again. If the problem persists, replace the needle with a new one.
  • M
    Michael ClarkeSep 14, 2025
    What to do if MTS needle is connected but temperature is not registered on the Procedure Screen of BTG ICEfx Medical Equipment?
    • E
      edwardscoleSep 14, 2025
      Move the MTS needle to a different port. If the issue persists, replace the MTS needle. If problems continue, contact Galil Medical Customer Service.
  • M
    Megan AdamsSep 12, 2025
    What to do if a needle is not recognized by BTG Medical Equipment?
    • A
      Austin WhiteSep 12, 2025
      Move the needle to a different port. If the system still does not recognize the needle, press the Channel button to display the needle type drop-down list and select the needle type from the list.
  • A
    Anthony BishopSep 13, 2025
    What to do if not all of the expected temperature sensor locations on the MTS needle are registered on the Procedure Screen of BTG ICEfx?
    • N
      Nicole RhodesSep 13, 2025
      On the Settings Screen, select the desired number of sensors to display. If the issue persists, move the MTS needle to a different port, or replace the MTS needle. If problems continue, contact Galil Medical Customer Service.
  • S
    Sarah SimonSep 5, 2025
    What to do if needle cannot be firmly connected in the needle port of BTG Medical Equipment?
    • A
      amy12Sep 5, 2025
      Verify that the locking bar is in the UNLOCKED position. If the needle connector may be defective, use a different needle. If residual gas pressure may be in the needle port, use a different channel. Check the Gas Indicator display. If there is pressure in the system, end the procedure and open the Vent Valve on the rear of the system to completely vent the system.
  • W
    William Rodriguez IISep 2, 2025
    What to do if BTG ICEfx Medical Equipment doesn't allow testing of a needle in a locked channel?
    • D
      danieldawnSep 2, 2025
      Verify that the system is at operating pressure. Also, verify that the Argon Shutoff Valve is in the ON position to allow sufficient gas flow. If necessary, further open the argon cylinder valve by turning the valve counterclockwise to allow sufficient gas flow, and verify that appropriate pressure is displayed on the Gas Indicator.

Summary

System Overview

Brief Description

Provides an overview of the ICEfx Cryoablation System and its function.

How Supplied

Details the components included with the ICEfx Cryoablation System and accessories.

Intended Use

Defines the system's purpose and indications for cryoablative tissue destruction.

Indications

Lists the specific medical fields and conditions for which the system is indicated.

Contraindications

States any conditions or situations where the system should not be used.

Warnings

Highlights critical safety information and potential hazards associated with system use.

Precautions

Outlines important steps and considerations for safe operation and handling.

Potential Adverse Events

Lists potential side effects or complications that may occur during or after procedures.

System Description

Console

Describes the main unit of the ICEfx Cryoablation System, including its interface and ports.

ICEfx Cart

Details the optional cart used for supporting and moving the ICEfx Console.

System Setup

Preparation for Use

Steps to inspect and prepare the system components before operation.

Attaching the Console to the ICEfx Cart

Instructions for securing the Console onto the ICEfx Cart.

Setting up the Console

Procedure for powering on, configuring, and logging into the system.

Connecting the Argon Gas

Steps for safely connecting the argon gas supply to the system.

Getting Started With the User Interface

Document Conventions

Explains the typesetting conventions used throughout the user manual.

Logging In

Details the process for accessing the system software via username and password.

Navigating the User Interface

Guides users on how to interact with the system's graphical interface.

Starting the Procedure

Initiates the cryoablation procedure setup and wizard.

Entering Case Information

Optional step to input patient and procedure-specific details.

Using the Procedure Screen

Describes the main interface for controlling and monitoring cryoablation.

Reports

Information on viewing, saving, and exporting procedure reports.

Configuring Settings

Options for customizing system parameters and user preferences.

Administrative Options

Access to advanced features like software updates and user management.

Performing the Cryoablation Procedure

Pre-Procedure Needle;MTS Testing

Essential steps to test needles and sensors before patient treatment.

Performing a Cryoablation Procedure

Detailed steps for conducting the cryoablation treatment.

System Shutdown

Shutting Down the System

Procedures for safely powering off and venting the system.

Removing the Console from the Cart

Instructions for detaching the Console for storage or service.

System Care and Maintenance

Cleaning the ICEfx Cryoablation System

Guidelines for cleaning the system components after use.

Service and Preventive Maintenance

Information on scheduled maintenance and authorized service.

System Disposal

Procedures for decommissioning and disposing of the system.

Troubleshooting

Software Recovery

Steps to restore or update the system software in case of failure.

Electronics, Electrical and User Error Related Issues

Troubleshooting for hardware, electrical, and user-caused problems.

Gas Issues

Solutions for problems related to argon gas supply and pressure.

Mechanical Issues

Guidance for resolving issues with physical components of the system.

Gas Cylinder and Gas Supply Line

Troubleshooting for problems with gas cylinders and supply lines.

Needles

Specific troubleshooting steps for cryoablation needles.

Multi-Point Thermal Sensors

Solutions for issues related to MTS sensor readings and connectivity.

Displayed Messages

Explanation of system messages and recommended actions for errors.

System Specifications

Operating Conditions

Defines the environmental parameters for system operation.

Storage Conditions

Specifies the temperature and humidity ranges for system storage.

Transportation Conditions

Guidelines for safely transporting the ICEfx Cryoablation System.

Mechanical Specifications

Details the physical dimensions, weight, and footprint of the system.

Argon Gas Supply

Requirements for the argon gas used with the system.

Gas Cylinder Specifications

Information on pressure and volume for gas cylinders.

Accuracy of Displayed Values

Specifies the precision of system measurements for temperature and pressure.

Electrical Specifications

Provides details on power input, frequency, and ports.

Essential Performance

Defines the core functional capabilities of the ICEfx System.

References

Patents

Information on patents covering the ICEfx Cryoablation System.

Trademarks

Lists trademarks associated with the system and related products.

Contact

Provides contact information for Galil Medical Customer Service and support.

Disclaimer of Warranty