M-Series Operator’s Manual 4/9/15 15-13
Number Message Cause & Effect Action
924 File read error Problem reading the job file, this error
occurs if the file was opened successfully
but there was an error while reading the
file.
925 Error reading job file same as above at a different place in the
code
926 Failed to locate job
continuation position
Job continuation from the Run Menu
failed.
Do a Run/Search
927 Too many subprogram
calls
Nesting level of subprograms is too high.
I.e. a subprogram calls another subprogram
which calls another subprogram, which
calls another subprogram, etc…
928 Error Loading Log
Configuration file…
Using defaults
There was an error while loading the log
configuration file. Default settings will be
used.
929 Log Level set to __ The logging level parameter (P140) has
been changed.
930 Log Level
Configuration file not
found… Creating new
configuration.
The log level configuration file was not
found. A default file will be created.
932 Error during Tool
Check
A general error condition occurred when
the Tool Check key was pressed.
933 Log file initialized There was an error in trimming the log file,
or the log file did not exist, so a new log
file has been created.
934 Warning: Excess
precision truncated
A CNC program is using axis positioning
precision greater than what is displayed,
and therefore the actual commanded
positions are truncated. This happens
when the Simultaneous Contouring feature
was not enabled. This feature must be
enabled for the extra precision to be
acknowledged.
Contact Dealer for
information about obtaining
the Simultaneous
Contouring feature.
935 _ axis (#) scale
disabled
A scale is enabled for this axis but
compensation was disabled. Scale
compensation is disabled at initial power
up, configuration changes, and during
homing moves.
Home the machine.
935 Probe failed reset
retries
Probe failed to reset after 3 tries. The
probing operation may have been started
too close to the surface.
Move probe further away
from surface and do
probing operation again. If
this continues to fail
persistently, call dealer.
936 _ axis (#) scale
enabled
A scale is enabled for this axis and
compensation was enabled. This happens
after homing the axis.
Not Applicable
936 Probe failed to reset Probe failed to reset. The probing
operation may have been started too close
to the surface.
Move probe further away
from surface and do
probing operation again. If
this continues to fail
persistently, call dealer.
944 MPU requested resend The MPU requested a resend Status Message
945 PC requested resend The PC requested a resend Status Message

Table of Contents