Enter/Exit Programming Mode UPC-A
136 Gryphon™ I GD/GBT/GM4500
Expand UPC-A to EAN-13
Expands UPC-A data to the EAN-13 data format. Selecting this feature also
changes the symbology ID to match those required for EAN-13.
DEFAULT
UPC-A to EAN-13 = Don’t Expand
UPC-A to EAN-13 = Expand
UPC-A Number System Character Transmission
This feature enables/disables transmission of the UPC-A number system char-
acter.
UPC-A Number System Character = Do not transmit
UPC-A Number System Character = Transmit
DEFAULT
$CAB3B00
$CAB3B01
$CABNS00
$CABNS01